Altronix AL400ULACM Power Supply

Your Price: $335.75
Retail Price:$509.33
You Save:$173.58(34%)
Power Supply/Access Power Controller, Input 115VAC 60Hz at 3.5A, 8 Fused Outputs, 12VDC at 4A or 24VDC at 3AGrey Enclosure
Part Number : ALT_AL400ULACM
Availability: 87 In Stock.
Altronix AL400ULACM Power Supply

12VDC 4A supply current or 24VDC 3A supply current. Class 2 rated power limited outputs. Fuse protected outputs. 15.5inH x 12inW x 4.5inD
  • Input:
  • Input 115VAC 60Hz rated @ 3.5 amp.
  • Power supply input options:
  • a) One (1) common power input for ACM8 and lock power (factory installed).
  • b) Two (2) isolated power inputs - One (1) to power the ACM8 and one (1) for lock accessory power, (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10 amp total.
  • Eight (8) Access Control System trigger inputs. Input options:
  • a)Eight (8) normally open (NO) inputs.
  • b)Eight (8) open collector inputs.
  • c)Any combination of the above.
  • Output:
  • 12VDC or 24VDC outputs.
  • 12VDC @ 4 amp supply current or 24VDC @ 3 amp supply current.
  • Class 2 Rated power-limited outputs.
  • Eight (8) independently controlled outputs.
  • Output options:
  • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • b) Eight (8) form "C" 5 amp rated relay outputs
  • c) Any combination of the above.
  • Eight (8) auxiliary power outputs (unswitched)
  • Output ratings:
  • Fuses are rated @ 3.5 amp.
  • Filtered and electronically regulated outputs (built-in power supply).
  • Supervision:
  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery and battery presence supervision (form "C" contact).
  • Features:
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.
  • Visual Indicators:
  • Red LEDs indicate outputs are triggered (relays energized).
  • Green LED indicates FACP disconnect is triggered.
  • AC input and DC output LED indicators.
  • Battery Backup:
  • Built-in charger for sealed lead acid or gel type batteries.
  • Power Supply Board maximum charge current 0.7 amp.
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Electrical:
  • Operating temperature: 0° C to 49° C ambient.
  • ACM8 board main fuse is rated at 10 amp.
  • BTU/Hr.:
  • 12VDC: 24.57 BTU/Hr.
  • 24VDC: 36.85 BTU/Hr.
  • Mechanical:
  • Enclosure Dimensions (H x W x D approx.): 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm)
  • Combination knockouts are 0.625" and 0.75"
  • Accommodates up to two (2) 12AH batteries.
  • Product weight (approx.): 10.7 lbs. (4.85 kg).
  • Shipping weight (approx.): 12 lbs. (5.44 kg).

Features

  • b)Eight (8) open collector inputs.
  • Input:
  • Battery Backup:
  • a)Eight (8) normally open (NO) inputs.
  • b) Eight (8) form "C" 5 amp rated relay outputs
  • Enclosure Dimensions (H x W x D approx.): 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm)
  • Fire Alarm disconnect input options:
  • b) Polarity reversal input from FACP signaling circuit.
  • Visual Indicators:
  • Eight (8) independently controlled outputs.
  • c)Any combination of the above.
  • Electrical:
  • Fuses are rated @ 3.5 amp.
  • Features:
  • Power Supply Board maximum charge current 0.7 amp.
  • BTU/Hr.:
  • AC input and DC output LED indicators.
  • Combination knockouts are 0.625" and 0.75"
  • Automatic switch over to stand-by battery when AC fails.
  • Shipping weight (approx.): 12 lbs. (5.44 kg).
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Output options:
  • Green LED indicates FACP disconnect is triggered.
  • 12VDC @ 4 amp supply current or 24VDC @ 3 amp supply current.
  • ACM8 board main fuse is rated at 10 amp.
  • Eight (8) Access Control System trigger inputs. Input options:
  • Low battery and battery presence supervision (form "C" contact).
  • Input 115VAC 60Hz rated @ 3.5 amp.
  • a) One (1) common power input for ACM8 and lock power (factory installed).
  • Eight (8) auxiliary power outputs (unswitched)
  • Built-in charger for sealed lead acid or gel type batteries.
  • Supervision:
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Two (2) isolated power inputs - One (1) to power the ACM8 and one (1) for lock accessory power, (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10 amp total.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Output ratings:
  • Mechanical:
  • 24VDC: 36.85 BTU/Hr.
  • Short circuit and thermal overload protection.
  • AC fail supervision (form "C" contacts).
  • c) Any combination of the above.
  • Red LEDs indicate outputs are triggered (relays energized).
  • 12VDC: 24.57 BTU/Hr.
  • Accommodates up to two (2) 12AH batteries.
  • Power supply input options:
  • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • 12VDC or 24VDC outputs.
  • Filtered and electronically regulated outputs (built-in power supply).
  • Product weight (approx.): 10.7 lbs. (4.85 kg).
  • Output:
  • Operating temperature: 0° C to 49° C ambient.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
  • Class 2 Rated power-limited outputs.

Attributes

Ship via: Can Ship UPS

Access Type: Power Supply

Alternate Codes: 136314, AL400ULACM

Category: Access Control, Alarm Power Supplies, Alarms & Intercom, Burglar Alarms, CCTV Products, Power Supplies, Wire & Power Supplies

Output Amps: 4/3AMPS

Output Volts: 12/24 VDC

Purpose: Access Control

Series: Altronix Power Supplies

Subtype: Power Supply

Type: Wire-In Transformer

Voltage/ Amp Rating: 12 - 24V DC